| Technical Specifications | |
|---|---|
| At a glance | |
| Models | NKS10 / NKS11 | Output: 140W / 360W |
| Tube voltage | 40–90 kV, adjustable in 1 kV steps |
| Tube current | 1.0–16 mA | Exposure: 5–2000 ms / 5–4000 ms |
| Weight | from 2 kg | Built-in rechargeable battery |
| Exposure control | remote control and hand switch |
| Imaging | compatible with DR flat panel detectors |
Bring the X-ray to the animal, not the animal to the X-ray room. The NKS10 and NKS11 are lightweight handheld X-ray units developed for veterinary practices, mobile clinicians, equine care and field work. The X-ray tube, high-frequency generator, control panel and rechargeable battery are integrated into one compact body, so you can produce digital radiographs on site — no shielded room, no darkroom and no stressful patient transport.

What Is a Handheld Veterinary X-Ray Machine?
A handheld veterinary X-ray machine is a portable radiography unit that generates X-rays from a battery-powered, hand-held body instead of a fixed installation. When high voltage is applied across the X-ray tube, electrons strike the tungsten target and release X-ray photons. These photons pass through the animal’s tissues: dense structures such as bone absorb more radiation, while soft tissue allows more to pass through. A digital flat panel detector captures the remaining beam and converts it into a radiographic image within seconds.
Compared with a stationary DR system, the NKS10 and NKS11 remove the need for a dedicated radiology room and heavy shielding construction. That makes radiography practical in clinics with limited space, in barns and stables, on farms, in animal shelters and during emergency field calls.
NKS10 vs NKS11: Which Model Fits Your Practice?
Both models share the same imaging principle, control interface and detector compatibility. The main differences are output power and sustained workload capacity.
| Item | NKS10 | NKS11 |
|---|---|---|
| Maximum output | 140W | 360W |
| Best for | Small animal clinics, light daily workload | Equine, farm work, frequent field calls |
| Tube voltage | 40–90 kV, 1 kV steps | 40–90 kV, 1 kV steps |
| Tube current | 1.0–16 mA | 1.0–16 mA |
| Exposure time | 5–2000 ms | 5–4000 ms |
| Weight | approx. 2 kg | approx. 3.5 kg |
| Exposure control | Remote / hand switch | Remote / hand switch |
| DR detector compatible | Yes | Yes |
Choose the NKS10 if your work is mainly companion-animal imaging in a clinic — limbs, foreign bodies and routine checks. Choose the NKS11 if you regularly image larger animals, work in stables or farms, or need more headroom for continuous daily shooting.

Key Features and Benefits
True Portability — One Case, One Imaging Room
At around 2 kg, the unit can be carried by one operator into a consulting room, a stable, a barn or a rescue scene. It packs into a carrying case, needs no installation and can be handed between examination rooms as workload demands.
High-Frequency Inverter for Stable Output
The high-frequency generator delivers stable high voltage with low ripple. Tube voltage and current are controlled precisely, reducing image noise and exposure fluctuation — helpful when assessing fine fracture lines, joint spaces and soft tissue swelling.
Battery Powered — Work Without Mains Supply
A built-in rechargeable battery powers the exposure itself, so the unit works during power cuts, in remote areas and at house calls. The supplied adapter accepts 100–240 V AC, 50–60 Hz for use in different countries.
Dual Exposure Control for Operator Safety
Trigger exposure either by remote control or by a two-stage hand switch (prepare, then expose). The operator can step back to a safer distance before radiating, reducing occupational exposure.
DR-Ready Digital Workflow
Pair the unit with a DR flat panel detector to build a complete digital radiography system. Images appear on a tablet or laptop within seconds and can be zoomed, adjusted, stored and exported — no film, no chemicals, no darkroom.
Built for Veterinary Workloads
Simple structure, few moving parts and straightforward controls mean less training time and easier maintenance. The interface supports fast parameter changes between species and body parts, which matters when the patient is stressed or in pain.
Applications
1Small animal practice: limb fractures, joint injuries, thoracic and abdominal imaging, ingested foreign bodies and dental radiographs in dogs, cats, rabbits and exotic pets.
2.Equine medicine: hoof, fetlock, cannon bone, knee and shoulder radiographs taken inside the stall — avoiding the risk of transporting an injured horse.
3.Farm and large animal work: on-site screening and local imaging for sheep, cattle and other animals that cannot be moved to a clinic.
4.Mobile and emergency veterinary services: field calls, rescue operations and disaster response where no fixed imaging facility exists.
5.Shelters and breeding facilities: batch health screening to identify hidden bone problems before they become severe.
6.Research and teaching: repeatable imaging data for animal studies and radiographic training in veterinary schools.
Limitations to be aware of: this handheld series is not intended for lumbar spine imaging and is not suitable for thick body parts of large adult animals. For those examinations, a higher-power stationary DR system is the appropriate choice.
Technical Specifications
| Specification | NKS10 | NKS11 |
|---|---|---|
| Maximum output power | 140W | 360W |
| Tube voltage | 40–90 kV, 1 kV step | 40–90 kV, 1 kV step |
| Tube current | 1.0–16 mA | 1.0–16 mA |
| Exposure time | 5–2000 ms | 5–4000 ms |
| Main unit dimensions | 185 × 135 × 75 mm (L×H×W), excluding collimator | 185 × 135 × 75 mm (L×H×W), excluding collimator |
| Weight | approx. 2 kg | approx. 3.5 kg |
| Power supply | Built-in rechargeable battery | Built-in rechargeable battery |
| Adapter input | 100–240 V AC, 50–60 Hz | 100–240 V AC, 50–60 Hz |
| Exposure control | Remote control / hand switch | Remote control / hand switch |
| Generator type | High-frequency inverter | High-frequency inverter |
| Imaging options | DR flat panel detector compatible | DR flat panel detector compatible |
What Is Included in the System
Because quotations differ by market and distributor, please confirm each item against your order:
1.NKS10 or NKS11 handheld X-ray unit
2.Collimator / beam limiting device
3.Hand switch and remote exposure control
4.Power adapter and rechargeable battery
5.Carrying case
6.DR flat panel detector and acquisition software
7.Lead apron, lead gloves and mobile shielding screen
Frequently Asked Questions
A.What is the difference between the NKS10 and NKS11?
They belong to the same handheld veterinary X-ray series and share tube voltage range, control methods and detector compatibility. The NKS10 is the lighter 140W model for routine companion-animal work; the NKS11 is the 360W version with greater capacity for repeated exposures and larger animals. Tell us your typical cases and we will recommend the right one.
B.Can the unit be used where there is no mains power?
Yes. The exposure is powered by the built-in rechargeable battery, so no mains outlet is needed at the point of care. The adapter accepts 100–240 V AC, 50–60 Hz, so it can be charged virtually anywhere. Carry a spare battery for long field days.
C.Which animals and body parts can be examined?
The units are designed for dogs, cats, rabbits, exotic pets, sheep, goats and local imaging of larger animals. Typical views include limbs, joints, thorax, abdomen, skull and teeth. The series is not intended for lumbar spine imaging or thick body parts of large adult animals.
D.Do I need a dedicated X-ray room?
No. There is no need to build a shielded radiology room. The unit can be used in a normal consultation room, a stable, a barn or outdoors, provided basic radiation protection measures are followed: lead clothing, collimation, distance and controlled access to the area.
E.What else do I need to produce digital images?
You need a DR flat panel detector to capture the image and a display device such as a tablet or laptop to view and store it. A collimator, hand switch, remote control and lead protective equipment complete the working setup. Check your quotation to see which of these are included.
F.How much training does the operator need?
The control panel is straightforward: kV is adjustable in 1 kV steps, commonly used views can be set as presets, and the two-stage hand switch separates preparation from exposure. An operator with basic radiographic knowledge can learn routine work after short training and hands-on practice.
G.Is NEWHEEK the original manufacturer?
Yes. Weifang Newheek Electronic Tech Co.,Ltd (NEWHEEK) manufactures X-ray equipment and accessories, including handheld and portable X-ray units, flat panel detectors, collimators, hand switches and high-voltage cables. The company operates under an ISO13485 quality system and its products carry CE and RoHS certification, with customers in more than 100 countries.
F.What about pricing, lead time and OEM options?
Pricing depends on the model, whether a DR detector and accessories are included, and order volume. Distributor pricing and tender support are available. Lead time and customisation options such as language interface, colour and accessory bundles are confirmed per order.
Tell us your clinic size, target animals, daily imaging volume and power conditions. We will send back a matched configuration and a clear quotation — not a generic catalogue.
+8619015366638
newheekcn@163.com
E-mail: newheekcn@163.com
Tel: +86 19015366638
Whatsapp:+86 19015366638
Company: Weifang Newheek Electronic Technology Co., Ltd.
ADD: E Building of Future Star Scientific Innovation Industrial Zone of No.957 Wolong East Street, Yulong Community, Xincheng Sub-District Office, Weifang Hi-tech Zone, Shandong Province, China